5 common problems in a light inverter and ways to solve them

5 common problems in a light inverter and ways to solve them

An essential device that will be found in a corner of virtually every home is an inverter. Even schools, offices, or public buildings are not exempt from this rule. When it comes to a push, these rectangular gadgets save the day. When there is a power outage, as inevitably happens, it is the inverter that provides electrical backup. The essence: the value of inverter batteries cannot be emphasized enough.

Now imagine a scenario. A home has the best of the best inverter installed from one of APC’s preferred UPS dealers. A few months later, there is a shortage of electricity. What follows is shocking. Instead of serving as a backup, the inverter does not work. There is no power to charge a mobile or to run the fan or even to turn on the light.

Unfortunately, this situation is relatively common. Like any other appliance installed in a residence, inverters are prone to failure. Fortunately, there are some problems that can be fixed at home. The solutions to the most common battery problems are discussed below.

  • The inverter does not turn on

The reasons why an inverter does not turn on are several:

  1. Inverter fired

  2. Battery disconnected

  3. Weak battery

  4. Low battery

  5. Loose terminals

  6. Inverted terminals

  7. Faulty switch

For each topic, there is a different outlet. A tripped inverter can be resolved by pressing the reset button on the device. If the ignition switch is causing a problem, have it repaired by a service center. In case the battery is faulty or faulty, it will need to be replaced. In the case of weak batteries, the best answer is to let it charge for a few hours, but if it is old, the best option is to buy a new one. For a terminal complication, inspect for corrosion, wipe off rust, and then grip firmly.

  • Constant beep alarm

When the inverter supports too much load, the alarm begins to sound. The only way to stop the beeping is to disconnect all the devices that are causing an additional load on the inverter. Another reason the alarm may squeak is when the cooling fan is stuck. The fan is necessary to maintain a cool temperature in the system while the inverter is running. If for some reason the fan does not work, the inverter will shut down or the alarm will beep.

The beep indicates that the unit is not operating in a safe condition and should be turned off. The key is to clean the fan and get it working again. If none of the strategies solve the problem, take the inverter to a service center.

  • LCD screen shows wrong codes

A common problem with LCD power inverters is false codes. The displayed numbers may be incorrect due to:

  1. External problem

  2. Internal problem

Internal problems are generally circuit related and can only be resolved by a qualified professional. The external complication can be resolved by:

  1. Inspecting the battery cables

  2. Checking the input or output cables

  3. Recheck the load

  • Low backup capacity

The only typical concern of investors is the very short backup time. The causes that lead to this problem can run the gamut:

  1. Too much power consumption – to solve it, eradicate all the extra load

  2. Incorrectly charged battery: to correct this, charge it continuously for a few hours ”.

  3. Low Electrolyte Level – To resolve this, refill the water using only distilled water to the recommended level. Always keep it somewhere in the middle of the minimum and maximum limit.

  • Battery refuses to charge

One problem some inverters face is that the battery won’t charge. This happens when:

  1. The battery is dead

  2. Rectifiers are burned out

  3. The fuses have blown

  4. Connections are loose

The first problem can only be solved by replacing the battery. The solution for the other three is to clean the terminals for corrosion. If nothing works, licensed help will be needed.

  • Sounds inside the inverter

One difficulty that several investors have is the noises that come from inside. The vital point to keep in mind is that each investor emanates certain sounds. It is standard. But sometimes the cooling fan collects a lot of dust and debris that produces strange clinks and noises. Clean the fan. You should take care of the sound. If the noise persists, replace the fan.

The Gist – Be practical

There was a time when investors were a luxury item that few could afford. Today’s environment of frequent power outages is no longer conducive to this thinking. Any place that houses people needs a backup and a bright inverter are excellent options. Knowing how to fix the minor faults that occur in all appliances can save you a lot of headaches. Be helpful, learn how to solve small investor-related problems, and save money, effort, and time spent hiring professionals.

Leave a Reply